Portable Instruments

HP Agilent Keysight N9330B

 Portable Instruments HP Agilent
Specifications:

  • Key Measurements & Applications
  • Frequency range: 25 MHz to 4 GHz
  • Frequency domain
  • Return loss vs. frequency, VSWR vs. frequency
  • Cable loss test
  • Distance to Fault (DTF)
  • Return loss vs. distance, VSWR vs. distance Standard Features
  • Sweep time: 3.0 ms/data point (full span, 521 trace point, CW sweep, typically)
  • Battery: Lithium-ion, 4 hours operating time
  • Support USB connectivity for memory stick and PC connection
  • 6.5″ TFT color LCD for indoor and outdoor use Optional Features
  • Precision mechanical short/open/50 ohm load, DC to 4 GHz, N (M)
  • Precision mechanical short/open/50 ohm load, DC to 4 GHz,7/16 DIN (M)
  • Electronic calibrator
  • Phase-stable extension cable 1.5 m, N (M) to N (F) Other Information
  • Condition: Used

HP-Agilent/Keysight – N9912A

 HP-Agilent/Keysight N9912A
Specifications:

  • Cable and antenna analyzer (CAT)
  • Vector network analyzer (VNA) – 2 MHz to 4/6 GHz
  • Directivity > 42 dB
  • CAT: Distance-to-fault, return loss, cable loss
  • VNA: S11 mag and phase, S21 mag
  • Time doman with gating Spectrum analyzer
  • Interference analyzer – 5 kHz to 4/6 GHz
  • DANL: -148 dBm, +18 dBm TOI
  • Spectrogram, waterfall display
  • Record and playback Independent source
  • Vector voltmeter (VVM)
  • Power sensor and channel power measurements
  • RF source: 2 MHz to 4/6 GHz
  • CW and tracking – VVM: 2 MHz to 4/6 GHz
  • Compare phase and electrical length
  • Average and peak power measurements with USB sensor
  • Channel power measurements: 100 kHz to 4/6 GHz
  • No sensor needed FieldFox instrument attributes
  • New: Remote control via iPad or iPhone
  • Standard 3-year warranty
  • Battery life: 4-hours
  • Weight: 2.8 kg or 6.2 lbs
  • Operating temperature: -10 to +55 °C (14 to 131 °F)
  • Condition: Used

Anritsu – MS2721A

 Portable Instruments Anritsu
 Specifications:

  • Frequency Range: 100 kHz to 7.1 GHz
  • Displayed Average Noise Level < -153 dBm typical in a 10 Hz resolution bandwidth at 1 GHz
  • RBWs: 10 Hz to 3 MHz in 1-3 sequence
  • VBWs: 1 Hz to 3 MHz in 1-3 sequence
  • Amplitude Accuracy +/- 0.5 dB typical 50-ohm
  • Interface standard RJ45 Ethernet 10/100 Base T and USB 2.0 Interfaces
  • AM, FM and SSB demodulation with built-in speaker and headset jack Handheld
  • Battery-operated
  • Design Large daylight viewable transflective color display
  • Built in pre-amplifier (standard) Lightweight 
  • Weight6.4 lbs (typical)
  • Quick Zoom-in, Zoom-out display in 1-2-5 sequence
  • Automatic or manual input attenuator control Dedicated
  • One-button measurements Trace Averaging Reference Level Offset Three traces
  • Store up to 2000 measurement test set-ups
  • Save up to 2000 measurement traces
  • Alphanumeric labeling of saved measurements
  • Automatic time and date stamp of saved data
  • Rechargeable/field-replaceable Li-Ion battery 6
  • Markers plus 6 delta markers Multi-segmented upper and lower limit lines 
  • Condition: Used